Harmonic Distortion Limit and Neutral Cable Sizing - Electric power & transmission & distribution (2024)

×

INTELLIGENT WORK FORUMS
FOR ENGINEERING PROFESSIONALS

Log In

Come Join Us!

Are you an
Engineering professional?
Join Eng-Tips Forums!

  • Talk With Other Members
  • Be Notified Of Responses
    To Your Posts
  • Keyword Search
  • One-Click Access To Your
    Favorite Forums
  • Automated Signatures
    On Your Posts
  • Best Of All, It's Free!

Join Us!

*Eng-Tips's functionality depends on members receiving e-mail. By joining you are opting in to receive e-mail.

Posting Guidelines

Promoting, selling, recruiting, coursework and thesis posting is forbidden.

Students Click Here

Eng-Tips Posting Policies

Contact US

thread238-521327

ForumSearchFAQsLinksMVPs

Harmonic Distortion Limit and Neutral Cable Sizing

Harmonic Distortion Limit and Neutral Cable Sizing

Edelma_1 (Electrical)

(OP)

Hello Everyone,

I found out from IEC 60364-5-52 that for a multiphase circuit you can actually reduce the size of the neutral conductor than it`s active size if the harmonic distortion current is less than 15%. I would like to know by how many percent can one reduce the neutral.

Replies continue below

Recommended for you

RE: Harmonic Distortion Limit and Neutral Cable Sizing

waross (Electrical)

While this has no standing in IEC land, it may be of interest:
The law in Canada:
(1) The neutral conductor shall have sufficient ampacity to carry the unbalanced load.
(2) The maximum unbalanced load shall be the maximum connected load between the neutral and any one
ungrounded conductor as determined by Section 8 but subject to the following:
(a) there shall be no reduction in the size of the neutral for that portion of the load that consists of
(i) electric-discharge lighting; or
(ii) non-linear loads supplied from a three-phase, 4-wire system; and
(b) except as required otherwise by Item (a), a demand factor of 70% shall be permitted to be applied
to that portion of the unbalanced load in excess of 200 A.
(3) The size of a service neutral shall be not smaller than the size of a neutral selected in accordance with
Subrule (1) and shall
(a) be not smaller than No. 10 AWG copper or No. 8 AWG aluminum; and
(b) be sized not smaller than a grounded conductor as required by Rule 10-204(2), except in service
entrance cable or where the service conductors are No. 10 AWG copper or No. 8 AWG aluminum.
(4) In determining the ampacity of an uninsulated neutral conductor run in a raceway, it shall be considered
to be insulated with insulation having a temperature rating not higher than that of the adjacent circuit
conductor

That said, it is common in Canada to have breaker panels supplied with a 200% neutral bus.

--------------------
Ohm's law
Not just a good idea;
It's the LAW!

RE: Harmonic Distortion Limit and Neutral Cable Sizing

Edelma_1 (Electrical)

(OP)

I actually read the standard half way, the full standards goes thus:

for multicore circuits the neutral conductor size can be smaller than the active size if the Harmonic distortion current is less than 15%.

When the Harmonics are between 15% to 33% the neutral conductor size shall be same size as the active conductor.

meanwhile the current THD should not exceed 20% of the fundamental frequency, in other words the neutral size should be same as conductor size for a nominal THD current of 20%.

RE: Harmonic Distortion Limit and Neutral Cable Sizing

che12345 (Electrical)

Edelma_1 (Electrical)(OP)25 Jul 24 15:10
"..I found out from IEC 60364-5-52 that for a multiphase circuit you can actually reduce the size of the neutral conductor than it`s active size if the harmonic distortion current is less than 15%....I actually read the standard half way, the full standards goes thus:....I would like to know by how many percent can one reduce the neutral".
1. I am an octogenarian, the IEC 60364-5-52 (2001) I have in my collection could be outdated/superseded. Please refer to the latest.
2. Per 2001 publication , in brief ... 523.8.3 ... if the harmonic current is greater than 10% the neutral conductor shall not be smaller than the phase conductors...and the corresponding reduction factors for higher harmonic currents are given in annex D.
Che Kuan Yau (Singapore)

RE: Harmonic Distortion Limit and Neutral Cable Sizing

Parchie (Electrical)

@EdeLma_1,
The formula I got is In/Ip = 3 X (per unit THD)/(sqrt(1+(per unit THD)^2) for circuits laden with 3rd harmonics. In = neutral current, and Ip = phase current.
I got 45% with 15% THD

RE: Harmonic Distortion Limit and Neutral Cable Sizing

Edelma_1 (Electrical)

(OP)

thanks Parchie,

asides using instruments to find out the THD, is it possible to get it by manual calculation first before proceeding to find voltage and current values of the harmonic orders?

RE: Harmonic Distortion Limit and Neutral Cable Sizing

che12345 (Electrical)

@ Mr Parchie (Electrical)26 Jul 24 06:43
"...The formula I got is In/Ip = 3 X (per unit THD)/(sqrt(1+(per unit THD)^2) for circuits laden with 3rd harmonics. In = neutral current, and Ip = phase currentI got 45% with 15% THD"
1. I am skeptical of the simplistic formula on the In/Ip value =..... Reason: the magnitude of In and Ip (unless further qualified) do NOT indicate the harmonic content.
2. To illustrate, consider a Y with N system:
a) 3 de-similar linear loads connected across AN, BN , CN. There will be current in the Neutral. The neutral current is the fundamental, with harmonic = 0.
b) 3 de-similar non-linear loads connected across AN, BN , CN. There will be current in the Neutral. The neutral current is the fundamental, + the arithmetical sum of the third harmonic currents etc., where harmonic current would NOT = 0.
3. Logically, neither the In nor Ip indicates the value of the harmonic current in the Neutral line.
Che Kuan Yau (Singapore)

Red Flag Submitted

Thank you for helping keep Eng-Tips Forums free from inappropriate posts.
The Eng-Tips staff will check this out and take appropriate action.

Reply To This Thread

Posting in the Eng-Tips forums is a member-only feature.

Click Here to join Eng-Tips and talk with other members! Already a Member? Login



News


Close Box

Join your peers on the Internet's largest technical engineering professional community.
It's easy to join and it's free.

Here's Why Members Love Eng-Tips Forums:

  • Harmonic Distortion Limit and Neutral Cable Sizing - Electric power & transmission & distribution (2)Talk To Other Members
  • Notification Of Responses To Questions
  • Favorite Forums One Click Access
  • Keyword Search Of All Posts, And More...

Register now while it's still free!

Already a member? Close this window and log in.

Join UsClose

Harmonic Distortion Limit and Neutral Cable Sizing - Electric power & transmission & distribution (2024)
Top Articles
ABO Energy GmbH : Aktionäre Vorstände Geschäftsführer und Unternehmensprofil | 576002 | DE0005760029 | MarketScreener
Richardson Funeral Home Leominster Obituaries
2022 Basketball 247
Stockmans Meat Company
Kool Online Offender Lookup
Look Who Got Busted New Braunfels
Wjbd Weather Radar
Best Taq 56 Loadout Mw2 Ranked
Immobiliare di Felice| Appartamento | Appartamento in vendita Porto San
Live2.Dentrixascend.com
The Blind Showtimes Near Merchants Walk Cinemas
Hallmark White Coat Ceremony Cards
Tabdil Tarikh
Pollen Count In Brandon Fl
Paperless Guide: Workflow
The Guardian Crossword Answers - solve the daily Crossword
Enloe Bell Schedule
Cyclefish 2023
What is IXL and How Does it Work?
Orlando Magic Account Manager
Optum Primary Care - Winter Park Aloma
Craigslist Storage Containers
Naval Academy Baseball Roster
Hope for recovery emerges for a Ukrainian soldier who suffered a severe brain injury 2 years ago
Ohio State Football Wiki
Toernooien, drives en clubcompetities
Disney Cruise Line
11 Nightlife Spots To Experience In Salem, Oregon
Logisch werving en selectie B.V. zoekt een Supply Chain & Logistics Engineer in Coevorden | LinkedIn
Configuring TPM 2.0 on a 6.7 ESXi host
Resident Evil Netflix Wiki
Nikki Catsouras Head Cut In Half
Orbison Roy: (1936 1988) American Singer. Signed 7 X 9
Horoscope Daily Yahoo
Family Naturist Contest
Jcpenney Salon Salinas
Unraveling The Mystery Behind Campinos Leaked: A Deep Dive
Plus Portal Ibn Seena Academy
Swissport Timecard
Make An Appointment Att
Danville Va Active Warrant List
Imagemate Orange County
Naviance Hpisd
Craigslist Pets Inland Empire
Katie Hamden Of
Honquest Obituaries
The Complete Guide to Chicago O'Hare International Airport (ORD)
Delta Rastrear Vuelo
Fetid Emesis
Csuf Mail
Penn Highlands Mon Valley | Penn Highlands Healthcare
Latest Posts
Article information

Author: Lakeisha Bayer VM

Last Updated:

Views: 5603

Rating: 4.9 / 5 (69 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Lakeisha Bayer VM

Birthday: 1997-10-17

Address: Suite 835 34136 Adrian Mountains, Floydton, UT 81036

Phone: +3571527672278

Job: Manufacturing Agent

Hobby: Skimboarding, Photography, Roller skating, Knife making, Paintball, Embroidery, Gunsmithing

Introduction: My name is Lakeisha Bayer VM, I am a brainy, kind, enchanting, healthy, lovely, clean, witty person who loves writing and wants to share my knowledge and understanding with you.